Electrophoresis

Electrophoresis

Power HC 3000 High-Current Power SupplyPower HC 3000 High-Current Power Supply
01

Power HC 3000 High-Current Power Supply

2024-06-07

① It can be automatically connected separated gel after concentrating gel.
② Automatically enter the micro-current state after electrophoresis to prevent the sample from spreading.
③ Safety protection function: monitoring of overvoltage, arc, no-load and sudden change of load; Overload/short circuit monitoring; Leakage protection; Open circuit alarm, automatic power-off recovery, pause/resume function, etc.

view detail
Power universal  600 universal electrophoresis power supplyPower universal  600 universal electrophoresis power supply
01

Power universal 600 universal electrophoresis power supply

2024-05-24

① Output type: constant voltage, constant current, constant power

② Protein function: After the concentrated gel, the power supply automatically connects to the separation gel, reducing the tediousness of manual resetting

③ Automatic rise function: After selecting the constant value, the other two indicators automatically rise to avoid the phenomenon of false constants caused by human operation

④ Microcurrent function: Automatically enter the microcurrent at the end of electrophoresis to avoid the diffusion of samples with timed shutdown and prevent the sample from running too far

⑤ Safety performance: overvoltage, arc, no-load and load mutation monitoring; overload/short circuit monitoring; leakage protection; open circuit alarm, automatic recovery from power failure, pause/resume function

view detail
Power basic 300 basic electrophoresis power supplyPower basic 300 basic electrophoresis power supply
01

Power basic 300 basic electrophoresis power supply

2024-05-14

1. Output type: constant voltage, constant current, constant power
2. Protein function: After the concentrated gel, the power supply automatically connects to theseparation gel, reducing the tediousness of manual resetting.
3. Automatic rise function: After selecting the constant value, the other two indicators automaticallynts caused by human operation.
4. Microcurrent function: Autornatically enter the microcurrent after the electrophoresis ends,avoiding the diffusion of samples with timed shutdown and preventing the samples from runningtoo far. 
5.Safety performance: overvoltage, arc, no-load and load mutation monitoring; overload/shortcircuit mitoring; leakage protection; open circuit alarm, automatic recovery from power failure,pause/lresume functior.
6. The LCD screen simultaneously displays voltage, current, power, and timing time.

view detail
Mini Vertical Electrophoresis CellMini Vertical Electrophoresis Cell
01

Mini Vertical Electrophoresis Cell

2024-05-14

① It can accommodate 1-4 hand-cast or pre-cast gels, and can complete up to 4 small gel electrophoresis within 1 hour

② The edge seal spacer is glued to the long glass plate to ensure the precise alignment of the glass plate and avoid gel leakage

③ The cam gel frame ensures precise alignment

④ It comes standard with 4 independent gel bases, which are convenient for flexible placement on narrow laboratory tables and can cast 4 gels at the same time

⑤ The comb with side teeth and built-in ridges isolates the gel from the air to avoid inhibiting the gel polymerization reaction

view detail